5200A Multiparameter Monitoring and Control Instrument

YSI Aquaculture Monitoring & Control Instrumentation

Engineered specifically for aquaculture systems, the YSI 5200A continuous multiparameter monitor, 5500D continuous optical dissolved oxygen monitor and AquaManager® Software can be used to integrate process control, feeding, alarming, and data management into one product or can be used to simply monitor one tank. Powerful enough to manage a full scale farming operation from anywhere in the world yet simple enough for anyone to use.

PriceDiscontinued

Option

SKU5200A-DC


Request a Quote For Replacement

This product has been discontinued and replaced with the IQ SensorNet process monitoring and control system. The IQ SensorNet offers enhanced capabilities and solutions for monitoring water quality in aquaculture facilities.

Designed specifically for Aquaculture Systems, the YSI 5200A,  AquaManager™ Software and AquaViewer II mobile app integrate process control, alarming, and data management into one solution. Simple enough to monitor one tank, powerful enough to manage a full scale farming operation from anywhere in the world. Simultaneously measure dissolved oxygen, pH, conductivity, ORP, salinity and temperature. YSI also offers a multi-channel dissolved oxygen monitor that can be networked with a 5200A or used independently. The 5500D can measure dissolved oxygen in up to four tanks/ponds using optical-based sensors which reduce maintenance and calibration requirements over traditional membrane-covered sensors.

  • Overview

    Engineered specifically for recirculating aquaculture systems, the YSI 5200A continuous monitor and AquaManager® Software can be used to integrate process control, feeding, alarming, and data management into one product or can be used to simply monitor one tank. Powerful enough to manage a full scale farming operation from anywhere in the world yet simple enough for anyone to use.

    Access your facilities water quality data at any time with the AquaViewer App from the App Store or manage your network with AquaManager desktop software.

    • Multiparameter monitor: DO, Temperature, Conductivity, pH, ORP, Salinity
    • Ethernet TCP/IP or wireless communications
    • Event logging records calibrations, high and low conditions and more
    • Conditional feed timer with Feed Smart software included
    • Networking capability up to 32 instruments per comm port or can be integrated with 5400 Multi DO monitors
    • Graphic, backlit LCD - quick, reliable system status checks
    • Plug-and-play...easy to install and maintain with user-scalability - no need to hire consultants
    • Flexible monitoring and control software
    • Email and SMS alarming

    Feed Smart software manages food delivery based on user-selectable inputs to manage feed delivery based on number of daily feedings, daily feed weights, total biomass and FCRs, along with parameter control based on water quality values. interfaces with most auto feeders.

    AquaManager desktop software provides the ability to instantly see an overview of your facility, manage parameter set points, and conveniently manage data to make informed operation decisions. If you're interested in a continuous monitor for dissolved oxygen, please visit the 5500D (optical dissolved oxygen) or 5400 (galvanic dissolved oxygen) page.

    The YSI IOEM and REM expansion modules increase the flexibility and capability of the YSI aquaculture platform when networked with 5200A, 5400 or 5500D instruments. Configure 4 (IOEM-4) or 8 (IOEM-8) analog channels as inputs or outputs for the ability to integrate 3rd party sensors or output from other devices. Outputs can be configured to control pumps, UV systems, analog valves, or send data to SCADA/ PLC systems. REMs (Relay Expansion Module) add relays where needed to control feeders, lighting, heaters, alarming, and more.

  • Specifications
    Buffer Recognition Yes
    Certifications RoHS, ETL, IP-65, NEMA 4X, CE, Made in USA, CUL, ULC
    Connectivity / Communications Ethernet and wireless optional. Output Relays: 4 each 10 amp 115 VAC (5 amp 230 VAC) relays for parameter, control and/or alarm E-mail and/or SMS alarming up to 3 e-mails with Ethernet module or up to 10 e-mails with AquaMana, RS-485 and RS-232 standard
    Data Management AquaManager™ Software integrates process control, alarming, and data management into one product
    Desktop Software Compatible AquaManager®, Windows 2000/XP/Vista/Windows 7 operating systems
    Display Back-lit graphic LCD (320 x 240) with timer, extended temperature range LCD
    Equipment used with 5562-4, or 20, or 30, AquaManager Desktop Software, 5561-4, 10, 20
    GLP Compliance Yes
    Logging Capabilities Yes
    Measurement Method / Channels DO, pH, ORP, conductivity, temperature, 2 user-configurable inputs, digital (0 to 1.0 VDC, 0 to 5.0 VDC or 4-20 mA) Timers: 4 timers - 10 events cascading events start/duration 1 feed timer channel (feeder not included), Feed Smart software manages feed
    Memory 1000 data, 1250 relay/alarm, 1000 entries/change and 500 GLP records, Non-volatile
    Monitoring Yes
    Multiparameter Yes
    Operating Temperature direct outside conditions with NEMA 4X enclosure, -15 to +70°C (5 to 158°F)
    Parameters Measured Dissolved Oxygen (electrochemical), pH,ORP/Redox, Conductivity, Specific Conductance, Salinity, Total Dissolved Solids (TDS), Temperature
    Power 12 V DC, mobile live haul or anytime AC power not available
    User Calibratable Yes
    User Replaceable Yes
    Warranty 2-years instrument; 1-year probes and cable
    Waterproof Yes
    Specification  
    Timers 4 timers - 10 events cascading events start/duration
    1 feed timer channel (feeder not included); Feed Smart software manages feed delivery, user-selectable inputs for number of daily feedings, daily feed weights, total biomass, FCRS and parameter control
    Field Upgradeable Software​ Yes; flash based
    Height 6.5 in, 16.5 cm
    Length 8.5 in, 21.6 cm
    Depth 4.75 in, 12.1 cm
    Parameter
    (units)
    Range Accuracy Resolution
    Dissolved Oxygen*
    (% saturation)
    0 to 500% 0 to 200%: ±2% or ±0.2 mg/L, whichever is greater;
    200 to 500%: ±6% of reading
    0.1% air saturation
    Dissolved Oxygen*
    (mg/L, ppm)
    0 to 60 mg/L 0 to 20 mg/L: ± 0.2 mg/L or ±2% of reading, whichever is greater;
    20 to 60 mg/L: ±6% of reading
    0 to 10 mg/L: 0.01 mg/L 
    10 – 60 mg/L: 0.1 mg/L
    Temperature
    (°C, °F)
    0 to +45°C (32 to 113°F) ±0.2°C 0.1°C
    Conductivity
    (µS, mS)
    0 to 200 µS;
    0 to 2000 µS
    0 to 20 mS;
    0 to 200 mS
    0 to 100 mS: ±0.5% of range​
    100 to 200 mS: ±1.0% of reading
    0.1 µS
    1 µS
    0.01 mS
    0.1 mS
    (range dependent)
    Salinity
    (ppt)
    0 to 80 ppt (0 to 50 ppt when entered manually) ±2% or ±0.1 ppt,
    whichever is greater
    0.1 ppt​
    pH
    (pH units)
    0 to 14 units ±0.2 units 0.01 units
    ORP
    (mV)
    -2000 to +2000 mV ±20 mV 1 mV

    *Polarographic dissolved oxygen sensor

    Specifications indicate typical performance and are subject to change.

  • Accessories

    AquaManager® Software

    AquaManager Software, Single and network use for 5200A, 5400, and 5500D instruments.

    Cap Membrane Kit 2.00 Mil PE

    Cap Membrane Kit 2.00 Mil PE (6 each), includes electrolyte (blue cap)

    REM-4 Relay Expansion Module

    Relay Expansion Module

    IOEM Input, Output Expansion Module

    Inputs and/or Outputs Expansion Module

    5562 Polarographic DO, Temperature, and Conductivity Cable

    The 5562 probe and cable assembly has replaced the discontinued 5561 probe and cable assembly.

    pH Kit

    pH Kit

    pH/ORP Kit

    pH/ORP Kit

    Zobell Solution, ORP Calibrator

    Zobell Solution, ORP Calibrator

    pH Buffer

    pH Buffer

    Conductivity Calibrator Solution

    Conductivity Calibrator Solution

    Internal Serial to Ethernet Device Kit

    Internal Serial to Ethernet Device Kit. Used with 5200A, 5400 and 5500D Instruments.

    5578 12-Volt Power Supply, 230 VAC Input

    12-Volt Power Supply, 230 VAC Input for 5200A, 5400, and 5500D instruments.

  • How to Order

    Step 1: Order Instrument

    SKU Description
    5200A-DC Multiparameter monitor, 12 VDC, power supply not included
    5200A-AC Multiparameter monitor, 110-240 VAC, with 115 VAC US cord
    606100 230 VAC cord, European
    606101 230 VAC cord, UK
    606102 230 VAC cord, Australia

    Step 2: Order Cable(s) and Sensors

    SKU Description
    5562-4, -10, or -20 4-, 10-, or 20-meter cable with polarographic DO probe/Temp/Conductivity and pH or pH/ORP (order separately)
    5564 pH Sensor Kit (order calibration solutions separately)
    5565 pH/ORP Sensor Kit (order calibration solutions separately)
    5204 DO Cap Membrane Kit, 2 Mil Polytetrafluoroethylene (6 caps with electrolyte)
    5909 DO Cap Membrane Kit, 2 Mil PE (6 caps with electrolyte)

    Step 3: Order Software, Communications & Mounting Accessories

    SKU Description
    5209A AquaManager Desktop Software
    5205 Probe Mounting Kit
    5285 RS232 Opto isolator
    5402 Serial to Ethernet Module
    6505 Weather Shield
    6506 Desiccant Kit
    6509 Rail Mount Kit
    6510 Panel Mount Kit
  • Video

    YSI Aquaculture Monitoring & Control Instrumentation

    Engineered specifically for aquaculture systems, the YSI 5200A continuous multiparameter monitor, 5500D continuous optical dissolved oxygen monitor and AquaManager® Software can be used to integrate process control, feeding, alarming, and data management into one product or can be used to simply monitor one tank. Powerful enough to manage a full scale farming operation from anywhere in the world yet simple enough for anyone to use.

  • Reviews
    Write a review
     

     

You may also need

ProDSS Multiparameter Digital Water Quality Meter

The Ultimate Sampling Handheld. Portable Meter for DO, Conductivity, Salinity, TDS, pH/ORP, Turbidity, Algae, Temperature and more

$2,053.50 - $2,701.50

IQ SensorNet 2020 3G Controller

Modular water quality monitoring system for a complete sensor network that measures up to 20 parameters

$2,570.00

IQ SensorNet FDO® Dissolved Oxygen Probes

Optical Dissolved Oxygen probe for IQ SensorNet systems

$2,000.00 - $2,290.00

IQ SensorNet SensoLyt® 700 IQ Sensors

The SensoLyt® provides continuous monitoring of pH or ORP for IQ SensorNet systems

$875.00 - $1,015.00

IQ SensorNet NOx

Optical Nitrate probe for IQ SensorNet systems. 

Request Pricing