1088 Rotary TOC Autosampler

PriceRequest Pricing

SKU321226


Have an Aurora 1030 TOC Analyzer? Meet its ‘right-hand man’ and your new favorite sampler instrument: the Model 1088 Rotary Autosampler, a brilliant tool that expedites analysis and ensures accuracy through automation.

  • Overview

    Make your analyses simple, quick, and accurate with our Model 1088 Rotary Autosampler. Specifically designed to work with all Aurora 1030 TOC Analyzer models (1030W, 1030C, and 1030S), this gem fits conveniently under the TOC analyzer. A removable 88-position autosampler tray loads the sample vials for fully-automated operation.

    The 1088 supports a number of special functions to address a range of sample conditions and analysis requirements. Onboard magnetic stirring ensures samples containing insoluble components or particles are homogeneous for sampling and accurate analysis. Septum piercing provides closed vial sampling to prevent contamination of the sample. System configuration for sample pretreatment allows pre-acidification and purging of samples within the 1088 prior to sampling. This technique removes the total inorganic carbon (TIC) content of samples, reducing the analysis time required for TOC measurements. A user-programmable number of rinses are used to clean the sample needle before the next vial is sampled.

    Model 1088 Features:

    • Automatically process up to 88 samples
    • Configurable for pre-acidification and sparging of sample TIC content within the autosampler to reduce TOC analysis time
    • Integrated wash station performs programmable rinse steps to clean the sampling needle and prevent cross-contamination
    • Magnetic stirring ensures insoluble and particulated samples are homogeneous for accurate results
    • Compact! Fits directly under the Aurora 1030 TOC Analyzer
    • Supports sampling from open vials and septum piercing of sealed vials
    • Large color touchscreen interface

  • Specifications
    General Instrument Specifications  
    Dimensions  
    1088 Autosampler 67.77 cm H x 38.1 cm W x 48.26 cm D
    (25.5 in H x 15 in W x 19 in D)
    1088 Autosampler and Aurora 1030 66 cm H x 47 cm W x 66 cm D
    (26 in H x 18.5 in W x 26 in D)
    Weight  
    1088 Autosampler 19 kg (42 lbs)
    1088 Autosampler and Aurora 1030 34.4 kg (76 lbs)
    Power Requirements 100-230 VAC ±10%; 50/60 Hz;
    150 W (max)
    Environment 15 - 35 °C operating temperature
    10 -90% relative humidity
    Sample Capacity 88 vials
    Sampling Needle 8.4 in, two-hole, stainless steel
    Sample Transfer Tubing 0.045" I.D. x 1/8" O.D. Teflon® tubing
    Vials 40-mL VOA vials
    Caps Open-hole caps
    Septa TFE-faced septa
    Sample Transfer Volume Range 10 µL - 10 mL
    Particulate Handling Up to 500 µm
    Special Functions Onboard magnetic stirring
    Septum piercing
    Sample pretreatment for TIC removal
    Certifications CE
    Communications RS-485 (Aurora 1030 analyzer to 1088 Autosampler)
    Warranty 12 months parts and labor

     

  • Accessories

You may also need

Aurora 1030W TOC Analyzer

TOC Analyzer

Request Pricing

ATOC Software

Automated Data Management Software

Request Pricing

Aurora 1030D TOC Analyzer

TOC Analyzer

Request Pricing

1030S Solids Analysis Module

Solids Combustion Module

Request Pricing

1080 Total Organic Carbon (TOC) Analyzer

TOC Combustion Analyzer

Request Pricing